cman-2.0.115-124.el5_11.4.src
[995 KiB] |
Changelog
by Marek Grac (2016-08-17):
- fencing: Invalid string concatenate
Resolves: rhbz#1206604
|
cman-2.0.115-124.el5.src
[994 KiB] |
Changelog
by Christine Caulfield (2014-03-24):
- qdisk: Make qdiskd warn if not all nodes are running qdiskd
Resolves: rhbz#994187
- qdisk: Waits tko cycles to complete initialization instead of tko_up
Resolves: rhbz#1029191
|
cman-2.0.115-118.el5_10.4.src
[991 KiB] |
Changelog
by Marek Grac (2014-03-07):
- fencing: fence_vmware_soap does not respect delay
Resolves: rhbz#1073821
|
cman-2.0.115-118.el5_10.3.src
[991 KiB] |
Changelog
by Christine Caulfield (2013-12-17):
- gfs_controld: fix plock recovery
Resolves: rhbz#bz1043358
|
cman-2.0.115-118.el5_10.1.src
[986 KiB] |
Changelog
by Marek Grac (2013-10-23):
- fencing: fence_cisco_ucs does not respect delay
Resolves: rhbz#994228
|
cman-2.0.115-118.el5.src
[985 KiB] |
Changelog
by Marek Grac (2013-06-18):
- fencing: Fix problem introduced by 'Add support for APC 5.x'
Resolves: rhbz#886612
|
cman-2.0.115-109.el5_9.6.src
[981 KiB] |
Changelog
by Christine Caulfield (2013-12-17):
- Fix plock recovery that could result in 2 nodes being granted the same lock
Resolves: rhbz#1043356
|
cman-2.0.115-109.el5_9.5.src
[978 KiB] |
Changelog
by Marek Grac (2013-09-28):
- fence_ipmilan: return code can be invalid
Resolves: rhbz#1012567
|
cman-2.0.115-109.el5_9.4.src
[978 KiB] |
Changelog
by Marek Grac (2013-07-31):
- fencing: Solve regression with Dell DRAC 5/CMC due to invalid EOL
Resolves: rhbz#986981
|
cman-2.0.115-109.el5_9.3.src
[977 KiB] |
Changelog
by Fabio M. Di Nitto (2013-04-20):
- fenced: Prevent a rare but possible spinning in poll on the cman fd
Resolves: rhbz#951049
|
cman-2.0.115-109.el5_9.1.src
[975 KiB] |
Changelog
by Fabio M. Di Nitto (2013-03-20):
- cman|fenced: Fix node killing in case of a 2node cluster that suffers
brief network outage
Resolves: rhbz#923861
|
cman-2.0.115-109.el5.src
[974 KiB] |
Changelog
by Marek Grac (2012-10-12):
- fence_rhevm: New href attrivute in RHEV-M 3.1 API
Resolves: rhbz#863567
|
cman-2.0.115-96.el5_8.4.src
[950 KiB] |
Changelog
by Marek Grac (2012-10-02):
- fence_vmware_soap: Improve speed of fencing and fix issues with VM without valid UUID
Resolves: rhbz#861392
|
cman-2.0.115-96.el5_8.3.src
[949 KiB] |
Changelog
by Marek Grac (2012-04-18):
- fencing: if "delay" option is used then fencing can timeout and fail
Resolves: rhbz#811939
|
cman-2.0.115-96.el5_8.1.src
[948 KiB] |
Changelog
by Marek Grac (2012-03-13):
- fence_rhevm: Incorrect power status detected when VM status is not up/down
Resolves: rhbz#795665
|
cman-2.0.115-96.el5.src
[948 KiB] |
Changelog
by Marek Grac (2012-01-09):
- fence_vmware_soap could not work with more than 100+ virtual machines
Resolves: rhbz#753797
|
cman-2.0.115-85.el5_7.3.src
[934 KiB] |
Changelog
by Lon Hohberger (2012-01-18):
- fence_rhevm: change "UP" status to "up" state as the REST-API has changed
fence_rhevm: REST API URL needs to be updated to /api
Resolves: rhbz#782833
|
cman-2.0.115-85.el5_7.2.src
[933 KiB] |
Changelog
by Fabio M. Di Nitto (2011-09-22):
- cman init: fix FENCED_OPTS shell escaping
Resolves: rhbz#740181
|
cman-2.0.115-85.el5_7.1.src
[932 KiB] |
Changelog
by Fabio M. Di Nitto (2011-08-18):
- cman: allow init script to pass options to fenced
Resolves: rhbz#731306
|
cman-2.0.115-85.el5.src
[932 KiB] |
Changelog
by Lon Hohberger (2011-06-29):
- fence_vmware_soap: Fix RHEL5-specific path issue
(fence_vmware_soap_fix_rhel5_specific_path_issue.patch)
Resolves: rhbz#717372
|
cman-2.0.115-68.el5_6.4.src
[900 KiB] |
Changelog
by Lon Hohberger (2011-05-24):
- qdiskd: Fix bad timer check - RHEL5
(qdiskd_fix_bad_timer_check_rhel5.patch)
Resolves: rhbz#707053
|
cman-2.0.115-68.el5_6.3.src
[900 KiB] |
Changelog
by Lon Hohberger (2011-04-27):
- ccs: Update manual page for ccs_tool
(ccs_update_manual_page_for_ccs_tool.patch)
Resolves: rhbz#677814
|
cman-2.0.115-68.el5_6.1.src
[898 KiB] |
Changelog
by Lon Hohberger (2010-12-20):
- fence-agents: Add man pages for ucs, ifmib, rhevm
(fence_agents_add_man_pages_for_ucs,_ifmib,_rhevm.patch)
Resolves: rhbz#664381
|
cman-2.0.115-68.el5.src
[895 KiB] |
Changelog
by Lon Hohberger (2010-12-10):
- fence_egenera: Fix log file location
(fence_egenera_log_file2.patch)
Resolves: rhbz#659090
|
cman-2.0.115-34.el5_5.4.src
[832 KiB] |
Changelog
by Marek Grac (2010-10-15):
- fence_ipmilan: Add power-wait option
(fence_agents_add_power_wait_to_fence_ipmilan.patch)
Resolves: rhbz#642700
|
cman-2.0.115-34.el5_5.3.src
[831 KiB] |
Changelog
by Lon Hohberger (2010-07-29):
- cman: Reduce consensus value
(cman_reduce_consensus_value.patch)
cman: fix consensus calculation
(cman_fix_consensus_calculation.patch)
Resolves: rhbz#618639
|
cman-2.0.115-34.el5_5.1.src
[828 KiB] |
Changelog
by Christine Caulfield (2010-05-25):
- fence_scsi: replace open3 calls with qx commands
- Resolves: rhbz#580158
|
cman-2.0.115-34.el5.src
[826 KiB] |
Changelog
by Christine Caulfield (2010-03-16):
- fencing: Fix fence_snmp so it returns an error code if the passphrase
is too short
- Resolves: rhbz#573834
|
cman-2.0.115-1.el5_4.9.src
[734 KiB] |
Changelog
by Christine Caulfield (2009-11-17):
- Fix fence_ipmilan read from unitialized memory
- Resolves: rhbz#537152
|
cman-2.0.115-1.el5_4.7.src
[733 KiB] |
Changelog
by Christine Caulfield (2009-11-16):
- scsi_reserve: fix error in regular expression
- Resolves: rhbz#529712
|
cman-2.0.115-1.el5_4.3.src
[728 KiB] |
Changelog
by Christine Caulfield (2009-09-30):
- Support for power cycle in fence ipmi
- Resolves: rhbz#522529
|
cman-2.0.115-1.el5_4.2.src
[724 KiB] |
Changelog
by Christine Caulfield (2009-09-03):
- fence_scsi support for 2 node clusters
- Resolves: rhbz#520823
|
cman-2.0.115-1.el5.src
[719 KiB] |
Changelog
by Chris Feist (2009-08-06):
- RSA II fencing agent has been fixed.
- Resolves: rhbz#493802
|
cman-2.0.98-1.el5_3.8.src
[708 KiB] |
Changelog
by Christine Caulfield (2009-08-20):
- Fix a situation where cman could kill the wrong nodes
- Resolves: rhbz#518060
|
cman-2.0.98-1.el5_3.7.src
[707 KiB] |
Changelog
by Chris Feist (2009-07-14):
- Quickly starting and stopping the cman service no longer leaves the cluster
in an inconsistent state
- Resolves: rhbz#510510
|
cman-2.0.98-1.el5_3.4.src
[704 KiB] |
Changelog
by Chris Feist (2009-06-09):
- Connections to openais are now allowed from unprivileged CPG clients with
user and group of 'ais'
- Resolves: rhbz#504531
|
cman-2.0.98-1.el5_3.1.src
[703 KiB] |
Changelog
by Chris Feist (2009-03-05):
- Fixed a bug which caused cman to eject nodes that are quorate without
any other nodes.
- Resolves: rhbz#487397
|
cman-2.0.98-1.el5.src
[703 KiB] |
Changelog
by Chris Feist (2008-12-03):
- Fixed failures with pythong telnet fencing agent.
- Resolves: rhbz#469066
|
cman-2.0.84-2.el5_2.3.src
[686 KiB] |
Changelog
by Chris Feist (2008-12-03):
- Added missing patch to allow delaying fence_tool joins.
- Resolves rhbz#474467
|
cman-2.0.84-2.el5_2.2.src
[685 KiB] |
Changelog
by Chris Feist (2008-11-17):
- The dirty flag is now honored for nodes that have not been seen
- A new option to delay the fence_tool join to solve some issues in certain
network configurations has been added.
- rgmanager now waits for the fence domain join to complete during startup.
- Resolves: rhbz#471273 rhbz#471415 rhbz#471272
|
cman-2.0.84-2.el5_2.1.src
[682 KiB] |
Changelog
by Chris Feist (2008-09-10):
- cman_tool nodes -a no longer loops indefinitely on most clusters
- Resolves: rhbz#460065
|